신고사유
신고해주신 내용은 쇼핑몰 운영자의 검토 후 내부 운영 정책에 의해 처리가 진행됩니다.
상품명 | QuicKey Pro Human AMH(Anti-Mullerian Hormone) ELISA Kit |
---|---|
판매가 | 300,000원 |
월 렌탈 금액 |
월 0원 (개월 기준)
|
---|
구매방법 | |
---|---|
배송주기 |
정기배송 할인 save
|
SIZE | |
---|---|
옵션선택 |
(최소주문수량 1개 이상 / 최대주문수량 0개 이하)
사이즈 가이드할인가가 적용된 최종 결제예정금액은 주문 시 확인할 수 있습니다.
Get more sensitive and precise results with saving at least 1-2h comparing to traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way.
Assay type | Sandwich-ELISA |
Format | 96T/48T/24 |
Assay time | 1.5h |
Detection range | 78.13-5000 pg/mL |
Sensitivity | 46.88 pg/mL |
Sample type &Sample volume | serum and plasma; 50μL |
Specificity | This kit recognizes AMH in samples. No significant cross-reactivity or interference between AMH and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of AMH concentrations in serum and plasma. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips 48T: 8 wells ×6 strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T | 2-8℃, 1 months |
Reference Standard | 96T: 2 vials 48T/24T: 1 vial 96T*5: 10 vials | 2-8℃, use the reconstituted standard within 24h |
Concentrated HRP Linked Detection Ab(100×) | 96T: 1 vial, 60 μL 48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL | 2-8℃(Protect from light) |
Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL 96T*5: 5 vials, 20 mL | 2-8℃ |
HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL 96T*5: 5 vials, 14 mL | |
Concentrated Wash Buffer(25×) | 96T/48T/24T: 1 vial, 30 mL 96T*5: 5 vials, 30 mL | |
Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL | 2-8℃ |
Plate Sealer | 96T/48T/24T: 5 pieces 96T*5: 25 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level AMH were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level AMH were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 249.73 | 653.82 | 2390.54 | 261.16 | 616.25 | 2312.39 |
Standard deviation | 16.71 | 28.64 | 114.51 | 16.32 | 28.16 | 116.78 |
CV (%) | 6.69 | 4.38 | 4.79 | 6.25 | 4.57 | 5.05 |
The recovery of AMH spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 83-96 | 90 |
EDTA plasma(n=8) | 91-106 | 96 |
Database Links | SwissProt: P03971 |
Synonyms | AMH,Anti-Mullerian Hormone |
Research Area | Cancer, Developmental biology, Signal transduction, Stem cells |